Troubleshooting Serial Connections
RS232 Control 53
Global Command to First Tile
Do you see your
command echoed
on the bottom
line of menu A1?
Is there a 13 at the
end of the decimal
display (second to
last line of the
menu)?
Is the command
spelled correctly?
Does the bytes
received number
increase when you
send a command?
Send a carriage return. Then
resend the command with a
carriage return at the end of it.
Resend the command with the
correct spelling.
Check that the first two
characters are the same case
(OP or op) not (Op or oP)
Do the UART framing
errors number
increase when you
send a command?
Check the wiring of connectors
and adapters. Be sure the
ground is connected.
Does the baud rate of
the tile match the
baud rate of the host?
Set the baud rate on either the
host or the tile so they match.
Check the wiring of connectors
and adapters.
Check the connection of the
serial cable.
Check that the program is
using the correct serial port.
Check that the cable is connected to the
RS232 In connection on tile A (not on
the RS485 connector).
No
Yes
No
No
Yes
No
Yes
Yes
No
Yes
Yes
Open the Serial Port Status
menu on all tiles.