External Control
110 Runco X-400d/X-450d Installation/Operation Manual
PRE
L
IMINAR
Y
Diagnostic Color DGC R/W No 0 6 No 0 = White
1 = Red
2 = Green
3 = Blue
4 = Yellow
5 = Cyan
6 = Magenta
Display Green Gain DGG R/W Yes -100 100 No
Display Green Offset DGO R/W Yes -100 100 No
DHCP DHC R/W No 0 1 No 0 = Off; 1 = On
Display Red Gain DRG R/W Yes -100 100 No
Display Red Offset DRO R/W Yes -100 100 No
Error Notification ERN R/W No 0 1 No 0 = Off; 1 = On
Error Code ERR R No 0 No 0 = None
1 = Display Lamp Overtemp
2 = Display Ballast Overtemp
3 = Display Fan Init Failure
4 = Display Fan 1 Failure
5 = Display Fan 2 Failure
6 = Display Fan 3 Failure
7 = Display Fan 4 Failure
8 = Display Fan 5 Failure
9 = Display Fan 6 Failure
10 = Display Fan 7 Failure
11 = Display Fan 8 Failure
12 = Display DMD Failure
13 = Display Lamp Strike Failure
14 = Display Lamp Went Out
15 = Display Ballast UART Failure
16 = Display GPIO Failure
17 = Display Lamp Door Open
18 = Display Processor Failure
19 = Display Hardware I2C Failure
20 = Display Software I2C Failure
21 = Display Lamp Error
22 = Display Communication Error
25 = DC-300 Fan 1 Failure
26 = DC-300 Fan 2 Failure
27 = DC-300 Overtemp 1
28 = DC-300 Overtemp 2
56 = DC-300 Fan 3 Failure
58 = DC-300 Overtemp 3
60 = DC-300 Input FPGA Failure
61 = DC-300 Output FPGA Failure
Focus FCS W Yes 0 0 No Send
(FCS+) or (FCS-) to
adjust incrementally
Film Mode FLM R/W No 0 1 No 0 = Off; 1 = On
Table 6-1. Serial Commands (continued)
Setting
Command
Code
Read/
Write
Inc/
Dec
Min
Value
Max
Value
String? Notes