External Control
108 D-73d Series Installation/Operation Manual
Error Code ERR R No 0 No 0 = None
1 = Display Lamp Overtemp
2 = Display Ballast Overtemp
3 = Display Fan Init Failure
4 = Display Fan 1 Failure
5 = Display Fan 2 Failure
6 = Display Fan 3 Failure
7 = Display Fan 4 Failure
8 = Display Fan 5 Failure
9 = Display Fan 6 Failure
10 = Display Fan 7 Failure
11 = Display Fan 8 Failure
12 = Display DMD Failure
13 = Display Lamp Strike Failure
14 = Display Lamp Went Out
15 = Display Ballast UART Fail-
ure
16 = Display GPIO Failure
17 = Display Lamp Door Open
18 = Display Processor Failure
19 = Display Hardware I2C Fail-
ure
20 = Display Software I2C Failure
21 = Display Lamp Error
22 = Display Communication
Error
25 = DC-300 Fan 1 Failure
26 = DC-300 Fan 2 Failure
27 = DC-300 Overtemp 1
28 = DC-300 Overtemp 2
56 = DC-300 Fan 3 Failure
58 = DC-300 Overtemp 3
60 = DC-300 Input FPGA Failure
61 = DC-300 Output FPGA Fail-
ure
Film Mode FLM R/W No 0 1 No 0 = Off; 1 = On
Fan 1 Speed FN1 R/W Yes 0 255 No
Fan 2 Speed FN2 R/W Yes 0 255 No
Firmware Upgrade FWU W No N/A N/A No Action will be performed on any
setting value
Gamma Advanced GMA R/W Yes 0 20 No
Gamma Mode GMM R/W No 0 1 No 0 = Simple
1 = Advanced
Gamma Simple GMS R/W No 0 6 No 0 = 2.0
1 = 1.8
2 = 2.2
3 = 2.35
4 = 2.5
Table 6-1. Serial Commands (continued)
Setting
Command
Code
Read/
Write
Inc/
Dec
Min
Value
Max
Value
String? Notes