Installation
52 D-73d Series Installation/Operation Manual
Dimension Digital Controller
1. Select Calibration -> Adjustment Mode
and set it to Secondary.
2. Select Service -> Test Video and choose
Secondary Alignment.
Projector (Align Secondary/Right
Image with Screen)
1. Align the image to the screen by
adjusting the Right (bottom) primary
lens zoom, focus and H/V offset.
2. Tighten the Right primary lens lock
screw.
3. D-73d/CineWide with AutoScope
only: Remove anamorphic lenses.
Set the AutoScope transport motor
AC switch to the “on” position.
Note: The default warp is 46 pixels on
the left and right sides (x) and 26 pixels
at the top and bottom (y). If more is
needed, use the “Image Alignment”
controls to increase it.
Dimension Digital Controller
1. For a ceiling-mounted (inverted) and/or
rear-projection installation, select
Service -> Display Device ->
Configure -> Installation ->
Picture Orientation and set it as needed.
2. Select Aspect Ratio and set it to Cinema.
On a D-73d/CineWide with AutoScope,
this should position the anamorphic lens
transport in front of the primary lenses.
3. Select Calibration -> Adjustment Mode
and set it to Primary.
4. Select Service -> Test Video and choose
Primary Alignment.
Projector
1. (Re-)install anamorphic lenses.
2. Align the primary (left-eye) image
with the screen by adjusting the Left
(top) anamorphic lens to produce the
least amount of distortion.
Dimension Digital Controller
1. Select Calibration -> Adjustment Mode
and set it to Secondary.
2. Select Service -> Test Video and choose
Secondary Alignment.
Projector
1. Align the secondary (right-eye)
image to the screen by adjusting the
Right (bottom) anamorphic lens to
produce the least amount of
distortion.
Dimension Digital Controller (Align
Secondary Image with Primary Image)
1. Select Aspect Ratio and set it to 16:9.
2. Select Calibration -> Adjustment Mode
and set it to Secondary.
3. Select Calibration -> Image Alignment ->
Corner Alignment, check the Primary
Test Pattern
and Secondary Test Pattern
boxes and adjust corners.
4. Select Calibration -> Image Alignment ->
Midpoint Alignment, check the Primary
Test Pattern and Secondary Test Pattern
boxes and adjust midpoints.
Projector
No adjustment needed.
Note: The Primary lens image is
usually left un-warped. This provides
the best image quality and will be
un-scaled for 1080p sources. You can
adjust the Primary image if needed,
however, by setting the Adjustment
Mode to Primary, checking the
Primary Test Pattern and Secondary
Test Pattern boxes and adjusting the
corners and/or midpoints prior to this
step.
Table 3-6. D-73d Optical Alignment Procedure (with Anamorphic Lenses) (continued)