Operation
88 D-113d Projection System Installation/Operation Manual
PRE
L
IMINAR
Y
Display Device - Configure: The options in the Display Device - Configure menu allow
you to change the picture orientation, perform lens adjustments or access other,
display-device specific functions.
•Installation – Orientation: Select Installation from the Display Device - Configure
menu, then select Orientation to change the picture orientation to suit the method of
installation (Floor Front or Floor Rear). Or, for front-projection installations, use the Auto
setting to have the projector automatically determine the orientation using an internal
sensor.
•Lens: Select Lens from the Display Device - Configure menu to access the motorized
lens controls. Refer to Adjusting the Focus, Zoom and Position of the Primary
Lenses on page 52.
•Display Info.: Select Display Info. from the Display Device - Configure menu to see the
projector serial number and lamp usage information (number of hours in service).
•Lamp Hours Reset: When you replace a projector lamp (refer to Lamp
Replacement on page 97), you should also reset its lamp hour counter to zero so that
the lamp usage information in the Display Info. window is accurate. To do this, select
Lamp Hours Reset from the Display Device - Configure menu. Then, select Lamp 1
Hours Reset or Lamp 2 Hours Reset. A confirmation dialog box appears. Select “Yes”
to continue with the reset or “No” to cancel the operation.
Lamp Calibration: When you replace a projector lamp (refer to Lamp Replacement
on page 97), you must calibrate the system to ensure that the Intensity setting works
correctly (refer to Lamp on page 81). To do this, select Lamp Calibration from the
Display Device - Configure menu. A confirmation dialog box appears. Select “Yes” to
continue with the calibration or “No” to cancel the operation. During calibration, which
takes about 90 seconds, the shutter is closed and no image is seen.
•Diagnostics: Select Diagnostics from the Display Device - Configure menu, then
select Red, Green, Blue, Yellow, Cyan or Magenta to display only that color channel
(simulating a filter of that color). This can be useful for calibration or measurement
purposes.
To restore the normal picture (all colors), select White.
Lens controls are not available when the Adjustment Mode is set to
Both (refer to Adjustment Mode on page 85).
After replacing a lamp, you must allow the projector to run for at
least five (5) minutes before performing a lamp calibration.